• Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor

Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vacuum
Samples:
US$ 126/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
208CAR
Poles Number
3
Type
Vacuum
Function
Vacuum
Certification
ISO9001-2000, CQC
Warranty
12 Month
Rated Voltatge
24kv
Rated Current
630A
Rated Short-Circuit Breaking Current
20ka
Mechanical Life
20000 Times
Shelf Life
20 Years
Transport Package
Standard Export Packing.
Specification
Vacuum
Trademark
ZGVE
Origin
Wenzhou
HS Code
8538900000
Production Capacity
180000pieces/Year

Product Description

Indoor 24KV Vacuum Interrupter For Vcb Vacuum Interrupter Contactor By ZGVEIndoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor





Main Technical Data
Main Technical Data
Rated Voltage  24kV
Rated Current  630/1250A
Rated Frequency 50Hz
Rated Short-time power frequency withstand voltage(1min) 42kV
Rated Lighting impulse withstand voltage 75kv
Rated short-circuit breaking current  25kA
Rated short-circuit making current(peak) 63kA
Breaking operations of rated short circuit breaking current 30 timies
Rated sigle capacitor bank breaking current  400A
Rated short-time withstand current 25kA
Rated peak withstand current 50/63kA
Rated duration of short-circuit 4s
Mechanica life 20000times
Contact closing force due to bellows and atmosphere 80±40N
Counterforce at rated contact stroke 120±50N
Circuit resistance at rated contact force  ≤25μΩ
Shelf life  20 years
Contact erosion limit 3mm
Weight of moving parts ≤1.3kg
Mechanical Data Required for matched vacuum switchgear
Rated contact stroke 10±1mm
Average opening speed  1.0±0.25m/s
Average closing speed  0.65±0.15m/s
Added contact force  2000±100N
Contact bouncing duration at closing operation ≤2ms
Contact bouncing bank amplitude of opening operation ≤2mm
Three-pole simultaneity ≤1ms

Dimensional Drawing

Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor



Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor
Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor


Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor
Indoor 24kv Vacuum Interrupter for Vcb Vacuum Interrupter Contactor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
49
Year of Establishment
2016-06-24